Milbank is proud to offer a series of air-cooled Home Standby Systems powered by Briggs & Stratton. Featuring affordable options from 7kW - 10kW, these systems offer a permanent, reliable solution to power outage and provide a continuous connection to natural gas or liquid propane for years of uninterrupted operation.
Model | MG07002-7kW | MG10001-10kW |
---|---|---|
Watts LP/NG | 7,000W (LP) / 6,000W (NG) | 10,000W (LP) / 9,000W (NG) |
Starting Watts LP/NG | 10,500 (LP) / 9,000 (NG) | 12,500 (LP) / 11,250 (NG) |
Operation | Fully Automatic | Fully Automatic |
Engine | 504cc Extended Life Series™ | 570cc Vanguard™ V-Twin |
Voltage | 120/240V AC, Single Phase, 1.0 pf | 120/240V AC, Single Phase, 1.0 pf |
Amps LP/NG | 29.1 (LP) / 25 (NG) | 41.7 (LP) / 37.5 (NG) |
Alternator Type | Automatic Voltage Regulator | Automatic Voltage Regulator |
Oil Warmer | Yes - Thermostatically Controlled (included) | Yes - Thermostatically Controlled (sold separately) |
Battery Warmer | Yes (sold separately) | Yes (sold separately) |
Full Pressure Lubrication | Yes | Yes |
Fuel Type | Propane (LP Vapor), Natural Gas | Propane (LP Vapor), Natural Gas |
Fuel Consumption† (at 1/2 Load ) |
33 FT3/HR Liquid Propane (LP), 80 FT3/HR Natural Gas (NG) |
35 FT3/HR Liquid Propane (LP), 84 FT3/HR Natural Gas (NG) |
Weekly Exerciser (Programmable) | Yes | Yes |
Sound Attenuation | Lo Tone™ Muffler | Sound Shield™ Technology |
Battery Charger | Yes | Yes |
Overcrank Protection | Yes | Yes |
Diagnostic Alerts with Remote System Status | Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch | |
Dimensions (L x W x H) |
32" x 34.25" x 38.5" | 32" x 34.25" x 38.5" |
Weight (generator only) |
299 lbs. | 335 lbs. |
Main Line Circuit Breaker | 30 Amp | 50 Amp |
Battery Requirements (not included) | 33 Amp Hour, 12 Volt DC, 350 CCA, AGM | 33 Amp Hour, 12 Volt DC, 350 CCA, AGM |
Total Harmonic Distortion | Less than 5% | Less than 5% |
Limited Warranty | 2 Years | 3 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating. † Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Model Number | MG0503120 | MG1003162 | MG1003002 | MG2003002 | MG1003992 | MG2003992 |
---|---|---|---|---|---|---|
Circuits | 12 | 16 | Whole House | Whole House | Whole House | Whole House |
Amps | 50A | 100A | 100A | 200A | 100A | 200A |
Service Entrance Disconnect | No | No | No | No | YES | YES |
Dimensions (L x W x H) |
14.25" x 6" x 21" | 14" x 6" x 24" | 12" x 6" x 16" | 12" x 6" x 22" | 16" x 7" x 22" | 16" x 7" x 30" |
Weight | 29 lbs. | 39 lbs. | 24 lbs. | 37 lbs. | 38 lbs. | 64 lbs. |
Common Features | 120/240 Voltage, 2 Poles, 50/60 Frequency, NEMA 3R Enclosure, UL 1008 Listed |
|||||
Power Management Method |
ACCM-II, Patented A/C Power Control Module™ | |||||
NOTE: Other manufacturers may not be compatible with Milbank’s generators or automatic transfer switches. |
Milbank is proud to offer a series of air-cooled Home Standby Systems powered by Briggs & Stratton. Featuring affordable options from 12kW - 20kW, these systems offer a permanent, reliable solution to power outage and provide a continuous connection to natural gas or liquid propane for years of uninterrupted operation.
Model | MG012001 - 12kW | MG17001 - 17kW | MG20003 - 20kW |
---|---|---|---|
Watts LP/NG | 12,000W (LP) / 11,000W (NG) | 17,000W (LP) / 15,300W (NG) | 20,000W (LP) / 18,000W (NG) |
Starting Watts LP/NG | 15,000 (LP) / 13,750 (NG) | -- (LP) / -- (NG) | -- (LP) / -- (NG) |
Operation | Fully Automatic | Fully Automatic | Fully Automatic |
Engine | 627cc Vanguard™ V-Twin | 993cc Vanguard™ V-Twin | 993cc Vanguard™ V-Twin |
Voltage | 120/240V AC, Single Phase, 1.0 pf |
120/240V AC, Single Phase, 1.0 pf |
120/240V AC, Single Phase, 1.0 pf |
Amps LP/NG | 50.0 (LP) / 45.8 (NG) | 67.0 (LP) / 60.0 (NG) | 83.3 (LP) / 75.0 (NG) |
Alternator Type | Automatic Voltage Regulator |
Automatic Voltage Regulator | Automatic Voltage Regulator |
Oil Warmer | Yes - Thermostatically Controlled (sold separately) | Yes - Thermostatically Controlled (sold separately) | Yes - Thermostatically Controlled (sold separately) |
Battery Warmer | Yes (sold separately) | Yes (sold separately) | Yes (sold separately) |
Full Pressure Lubrication | Yes | Yes | Yes |
Fuel Type | Propane (LP Vapor), Natural Gas | Propane (LP Vapor), Natural Gas | Propane (LP Vapor), Natural Gas |
Fuel Consumption† (at 1/2 Load ) |
41 FT3/HR Liquid Propane (LP), 102 FT3/HR Natural Gas (NG) |
-- | -- |
Weekly Exerciser | Yes | Yes | Yes |
Sound Attenuation | Sound Shield™ Technology | Sound Shield™ Technology | Sound Shield™ Technology |
Sound Rating (normal operation) | 65 dB | 68 dB | 68 dB |
Battery Charger | Yes | Yes | Yes |
Overcrank Protection | Yes | Yes | Yes |
Diagnostic Alerts with Remote System Status | Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch |
||
Dimensions (L x W x H) |
48.69" x 33.75" x 31.63" | 48.00" x 34.00" x 31.00" | 48.00" x 34.00" x 31.00" |
Weight (generator only) | 470 lbs. | 484 lbs. | 500 lbs. |
Main Line Circuit Breaker | 60 Amp | -- Amp | -- Amp |
Battery Requirements (not included) | 50 Amp Hour, 12 Volt DC, 600 CCA, AGM | 50 Amp Hour, 12 Volt DC, 600 CCA, AGM | 50 Amp Hour, 12 Volt DC, 600 CCA, AGM |
Total Harmonic Distortion | Less than 5% | Less than 5% | Less than 5% |
Limited Warranty | 4 Years | 4 Years | 4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating. † Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Model Number | MG1003162 | MG1003002 | MG2003002 | MG1003992 | MG2003992 |
---|---|---|---|---|---|
Circuits | 16 | Whole House | Whole House | Whole House | Whole House |
Amps | 100A | 100A | 200A | 100A | 200A |
Service Entrance Disconnect | No | No | No | YES | YES |
Dimensions (L x W x H) |
14" x 6" x 24" | 12" x 6" x 16" | 12" x 6" x 22" | 16" x 7" x 22" | 16" x 7" x 30" |
Weight | 39 lbs. | 24 lbs. | 37 lbs. | 38 lbs. | 64 lbs. |
Common Features | 120/240 Voltage, 2 Poles, 50/60 Frequency, NEMA 3R Enclosure, UL 1008 Listed | ||||
Power Management Method | ACCM-II, Patented A/C Power Control Module™ | ||||
NOTE: Other manufacturers may not be compatible with Milbank’s generators or automatic transfer switches. |
Milbank is proud to offer a series of liquid-cooled Home Standby Systems powered by Briggs & Stratton. Featuring affordable options from 30kW - 45kW, these systems offer a permanent, reliable solution to power outage and provide a continuous connection to natural gas or liquid propane for years of uninterrupted operation.
Model | MG30001 - 30kW | MG45001 - 45kW |
---|---|---|
Watts LP/NG | 30,000W (LP) / 27,000W (NG) | 45,000W (LP) / 45,000W (NG) |
Operation | Fully Automatic | Fully Automatic |
Engine | GM Vortec 3.0L inline 4 cylinder | GM Vortec 5.0L V8 |
Operating RPM | 1800 RPM | 1800 RPM |
Voltage | 120/240V AC, Single Phase, Electronic Regulation | 120/240V AC, Single Phase, Electronic Regulation |
Amps LP/NG | 125 (LP) / 112.5 (NG) | 187.5 (LP) / 187.5 (NG) |
Alternator Type | 4-pole, brushless | 4-pole, brushless |
Full Pressure Lubrication | Yes | Yes |
Fuel Type | Propane (LP Vapor), Natural Gas | Propane (LP Vapor), Natural Gas |
Fuel Consumption† (at 1/2 Load ) |
92 FT3/HR Liquid Propane (LP) 259 FT3/HR Natural Gas (NG) | 178 FT3/HR Liquid Propane (LP) 483 FT3/HR Natural Gas (NG) |
Weekly Exerciser | Yes | Yes |
Sound Attenuation | Sound Shield™ Technology | Sound Shield™ Technology |
Battery Charger | Yes | Yes |
Overcrank Protection | Yes | Yes |
Diagnostic Alerts with Remote System Status | Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch | |
Dimensions (L x W x H) |
84.5" x 39.5" x 41.5" | 98.5" x 39.5" x 44" |
Weight (generator only) |
1,800 lbs. | 2,100 lbs. |
Main Line Circuit Breaker | 150 Amp | 200 Amp |
Battery Requirements (not included) | 55 Amp Hour, 12 Volt DC, 650 CCA, VRLA | 55 Amp Hour, 12 Volt DC, 650 CCA, VRLA |
Total Harmonic Distortion | Less than 5% | Less than 5% |
Limited Warranty | 4 Years | 4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating. †Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Model Number | MG2003993 |
---|---|
Circuits | Whole House |
Amps | 200A |
Service Entrance Disconnect | Yes |
Dimensions (L x W x H) |
33" x 10.25" x 19" |
Weight | 64 lbs. |
Common Features | 120/240 Voltage, 2 Poles, 50/60 Frequency, NEMA 3R Enclosure, UL 1008 Listed |
Power Management Method | ACCM-III, Patented A/C Power Control Module™ |
NOTE: Other manufacturers may not be compatible with Milbank’s generators or automatic transfer switches. |
The electronic Control Center of the system, our Transfer Switches, powered by Briggs & Stratton, go well beyond the management of the transition from utlity service to your Home Generator System when the power goes out. These full-featured switches also include patented power management technologies that manage the power demands of up to two, 5-ton central air conditioners while protecting against power overload.
Model | MG0503120 | MG1003162 | MG1003002 | MG2003002 | MG1003992 | MG2003992 | MG2003993* |
---|---|---|---|---|---|---|---|
Circuits | 12 | 16 | Whole House | Whole House | Whole House | Whole House | Whole House |
Amps | 50A | 100A | 100A | 200A | 100A | 200A | 200A |
Service Entrance Disconnect | No | No | No | No | Yes | Yes | Yes |
Dimensions (L x W x H) |
14.25" x 6" x 21" | 14" x 6" x 24" | 12" x 6" x 16" | 12" x 6" x 22" | 16" x 7" x 22" | 16" x 7" x 30" | 33" x 10.25" x 19" |
Weight | 29 lbs. | 39 lbs. | 24 lbs. | 37 lbs. | 38 lbs. | 64 lbs. | 64 lbs. |
Common Features | 120/240 Voltage, 2 Poles, 50/60 Frequency, NEMA 3R Enclosure, UL 1008 Listed |
||||||
Power Mgmt. Method | ACCM-II, Patented A/C Power Control Module™ | ||||||
NOTE: Other manufacturers may not be compatible with Milbank’s generators or automatic transfer switches. * For liquid-cooled models only. |
Once you’ve selected a generator, selecting an automatic transfer switch requires that you focus on two things:
Service Amps: Milbank automatic transfer switches come in two sizes: 100 amps and 200 amps. To determine your needs, first take a look at the main breaker on your distribution panel. If you have a 200 amp main breaker (which is common in new homes), you will need a 200 amp WHOLE HOUSE automatic transfer switch. If you have a 100 amp main breaker (which is common in older homes), you will need a 100 amp WHOLE HOUSE automatic transfer switch.
Installation: Once you have selected a switch, there are basically two ways to install an automatic transfer switch:
Standard Installation: The most common option is to install it inside the home next to the main distribution panel. Your electrician will also need to install a sub-panel to manage the load properly.
Service Disconnect: Milbank also offers automatic transfer switches with “service entrance disconnect.” These outdoor transfer switches are connected directly to your home’s utility meter instead of the main circuit panel. The service disconnect option eliminates the need for the sub-panel.
Featuring patented computer-controlled technology, this Power Management System upgrade further expands your generator’s range and performance by automatically prioritizing and managing an additional four high-demand 240V appliances.
An oil heater and battery warmer are both thermostatically controlled to heat up when the temperature drops, ensuring smooth starting and engine operation. Items also available separately.
Battery Warmer Only - Model MG240100
Oil Heater Only - Model MG240101
Includes special UL air filter, pre-cleaner, spark plugs, oil filter, and synthetic oil.
![]() 7kW Series - Model MG070022> |
![]() 10-12kW Series - Model MG101222 |
![]() 15-20kW Series - Model MG151822 |
Kimber's, Inc., 115 N Geddes Street, Syracuse, NY 13204
Mailing Address: PO Box 11727, Syracuse, NY 13218-1727
No Reproduction of Kimber's, Inc. Content May Be Used Without Express Written Consent.
Apply for an Account | Power & Parts Lines | Paint & Body Lines |