Suggested Model |
MG07002-7kW |
Watts LP/NG |
7,000W (LP) / 6,000W (NG) |
Starting Watts LP/NG |
10,500 (LP) / 9,000 (NG) |
Operation |
Fully Automatic |
Engine |
504cc Extended Life Series™ |
Voltage |
120/240V AC, Single Phase, 1.0 pf |
Amps LP/NG |
29.1 (LP) / 25 (NG) |
Alternator Type |
Automatic Voltage Regulator |
Oil Warmer |
Yes - Thermostatically Controlled (included) |
Battery Warmer |
Yes (sold separately) |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Fuel Consumption†
(at 1/2 Load ) |
33 FT3/HR Liquid Propane (LP),
80 FT3/HR Natural Gas (NG) |
Weekly Exerciser (Programmable) |
Yes |
Sound Attenuation |
Lo Tone™ Muffler |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch |
Dimensions
(L x W x H) |
32" x 34.25" x 38.5" |
Weight
(generator only) |
299 lbs. |
Main Line Circuit Breaker |
30 Amp |
Battery Requirements (not included) |
33 Amp Hour, 12 Volt DC, 350 CCA, AGM |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
2 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG10001-10kW |
Watts LP/NG |
10,000W (LP) / 9,000W (NG) |
Starting Watts LP/NG |
12,500 (LP) / 11,250 (NG) |
Operation |
Fully Automatic |
Engine |
570cc Vanguard™ V-Twin |
Voltage |
120/240V AC, Single Phase, 1.0 pf |
Amps LP/NG |
41.7 (LP) / 37.5 (NG) |
Alternator Type |
Automatic Voltage Regulator |
Oil Warmer |
Yes - Thermostatically Controlled (sold separately) |
Battery Warmer |
Yes (sold separately) |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Fuel Consumption†
(at 1/2 Load ) |
35 FT3/HR Liquid Propane (LP),
84 FT3/HR Natural Gas (NG) |
Weekly Exerciser (Programmable) |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch |
Dimensions
(L x W x H) |
32" x 34.25" x 38.5" |
Weight
(generator only) |
335 lbs. |
Main Line Circuit Breaker |
50 Amp |
Battery Requirements (not included) |
33 Amp Hour, 12 Volt DC, 350 CCA, AGM |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
3 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG012001 - 12kW |
Watts LP/NG |
12,000W (LP) / 11,000W (NG) |
Starting Watts LP/NG |
15,000 (LP) / 13,750 (NG) |
Operation |
Fully Automatic |
Engine |
627cc Vanguard™ V-Twin |
Voltage |
120/240V AC,
Single Phase, 1.0 pf |
Amps LP/NG |
50 (LP) / 45.8 (NG) |
Alternator Type |
Automatic Voltage Regulator
|
Oil Warmer |
Yes - Thermostatically Controlled (sold separately) |
Battery Warmer |
Yes (sold separately) |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Fuel Consumption†
(at 1/2 Load ) |
41 FT3/HR Liquid Propane (LP),
102 FT3/HR Natural Gas (NG) |
Weekly Exerciser |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Sound Rating (normal operation) |
65 dB |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch
|
Dimensions
(L x W x H) |
48.69" x 33.75" x 31.63" |
Weight (generator only) |
470 lbs. |
Main Line Circuit Breaker |
60 Amp |
Battery Requirements (not included) |
50 Amp Hour, 12 Volt DC, 600 CCA, AGM |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG15001 - 15kW |
Watts LP/NG |
15,000W (LP) / 14,000W (NG) |
Starting Watts LP/NG |
18,750 (LP) / 17,500 (NG) |
Operation |
Fully Automatic |
Engine |
895cc Vanguard™ V-Twin |
Voltage |
120/240V AC,
Single Phase, 1.0 pf |
Amps LP/NG |
62.5 (LP) / 58.3 (NG) |
Alternator Type |
Automatic Voltage Regulator |
Oil Warmer |
Yes - Thermostatically Controlled (sold separately) |
Battery Warmer |
Yes (sold separately) |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Fuel Consumption†
(at 1/2 Load ) |
56 FT3/HR Liquid Propane (LP),
126 FT3/HR Natural Gas (NG) |
Weekly Exerciser |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Sound Rating (normal operation) |
65 dB |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch
|
Dimensions
(L x W x H) |
48.69" x 33.75" x 31.63" |
Weight (generator only) |
544 lbs. |
Main Line Circuit Breaker |
70 Amp |
Battery Requirements (not included) |
50 Amp Hour, 12 Volt DC, 600 CCA, AGM |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG17001 - 17kW |
Watts LP/NG |
17,000W (LP) / 15,300W (NG) |
Operation |
Fully Automatic |
Engine |
993cc Vanguard™ V-Twin |
Voltage |
120/240V AC,
Single Phase, 1.0 pf |
Amps LP/NG |
67.0 (LP) / 60.0 (NG) |
Alternator Type |
Automatic Voltage Regulator |
Oil Warmer |
Yes - Thermostatically Controlled (sold separately) |
Battery Warmer |
Yes (sold separately) |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Weekly Exerciser |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Sound Rating (normal operation) |
68 dB |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch
|
Dimensions
(L x W x H) |
48.0" x 34.0" x 31.0" |
Weight (generator only) |
484 lbs. |
Battery Requirements (not included) |
50 Amp Hour, 12 Volt DC, 600 CCA, AGM |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG20003 - 20kW |
Watts LP/NG |
20,000W (LP) / 18,000W (NG) |
Operation |
Fully Automatic |
Engine |
993cc Vanguard™ V-Twin |
Voltage |
120/240V AC,
Single Phase, 1.0 pf |
Amps LP/NG |
83.3 (LP) / 75 (NG)
|
Alternator Type |
Automatic Voltage Regulator |
Oil Warmer |
Yes - Thermostatically Controlled (sold separately) |
Battery Warmer |
Yes (sold separately) |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Weekly Exerciser |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Sound Rating (normal operation) |
68 dB |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch
|
Dimensions
(L x W x H) |
48.0" x 34.0" x 31.0" |
Weight (generator only) |
500 lbs. |
Battery Requirements (not included) |
50 Amp Hour, 12 Volt DC, 600 CCA, AGM |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG30001 - 30kW |
Watts LP/NG |
30,000W (LP) / 27,000W (NG) |
Operation |
Fully Automatic |
Engine |
GM Vortec 3.0L inline 4 cylinder |
Operating RPM |
1800 RPM |
Voltage |
120/240V AC, Single Phase, Electronic Regulation |
Amps LP/NG |
125 (LP) / 112.5 (NG) |
Alternator Type |
4-pole, brushless |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Fuel Consumption†
(at 1/2 Load ) |
92 FT3/HR Liquid Propane (LP) 259 FT3/HR Natural Gas (NG) |
Weekly Exerciser |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch |
Dimensions
(L x W x H) |
84.5" x 39.5" x 41.5" |
Weight
(generator only) |
1,800 lbs. |
Main Line Circuit Breaker |
150 Amp |
Battery Requirements (not included) |
55 Amp Hour, 12 Volt DC, 650 CCA, VRLA |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
Suggested Model |
MG45001 - 45kW |
Watts LP/NG |
45,000W (LP) / 45,000W (NG) |
Operation |
Fully Automatic |
Engine |
GM Vortec 5.0L V8 |
Operating RPM |
1800 RPM |
Voltage |
120/240V AC, Single Phase, Electronic Regulation |
Amps LP/NG |
187.5 (LP) / 187.5 (NG) |
Alternator Type |
4-pole, brushless |
Full Pressure Lubrication |
Yes |
Fuel Type |
Propane (LP Vapor), Natural Gas |
Fuel Consumption†
(at 1/2 Load ) |
178 FT3/HR Liquid Propane (LP) 483 FT3/HR Natural Gas (NG) |
Weekly Exerciser |
Yes |
Sound Attenuation |
Sound Shield™ Technology |
Battery Charger |
Yes |
Overcrank Protection |
Yes |
Diagnostic Alerts with Remote System Status |
Low Battery, Low Oil Pressure, Low Voltage, Fail to Start, Low Frequency, Engine Overspeed, High Temperature and Transfer Switch |
Dimensions
(L x W x H) |
98.5" x 39.5" x 44" |
Weight
(generator only) |
2,100 lbs. |
Main Line Circuit Breaker |
200 Amp |
Battery Requirements (not included) |
55 Amp Hour, 12 Volt DC, 650 CCA, VRLA |
Total Harmonic Distortion |
Less than 5% |
Limited Warranty |
4 Years |
NOTE: Natural gas fuel supply pressure at the generator’s fuel inlet port should be between 5 to 7 inches of water (in W.C.) at full load with all gas appliances turned on and operating. LP Gas fuel supply pressure should be 11 to 14 inches of water (in W.C.) at full load with all gas appliances turned on and operating.
† Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances – fuel flow rates may vary depending on these factors. Milbank reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. |
You need a commercial-grade generator.
Call us @ 800-627-1660 for our Commercial Generators.
|